site stats

Synthes recon nail

WebLocate the DHS angled guide and drill the outer cortex using the Drill Bit 2.0 mm (310.190). Page 9 If the guide wire is pulled out during reaming it must be replaced. Push the short DHS Centering Sleeve (338.180) into the drill hole and insert a DHS/DCS screw with the shaft foremost into the centering sleeve. WebThe Femoral Recon Nail (FRN) system is an integrated nailing system designed to adapt to multiple surgical approaches. As part of the DePuy Synthes portfolio, the FRN leverages …

Synthes Frn Inventory - Fill Online, Printable, Fillable, Blank pdfFiller

WebSynthes Femoral Recon Nail System - Orthopaedics - The Femoral Recon Nail System is intended for temporary fixation and stabilization of femoral shaft. WebThe DynaNail® TTC Fusion System is the ONLY fusion approach that offers the compression performance of an external fixator inside an intramedullary nail. Achieves 6 … military university of technology poland https://martinwilliamjones.com

Hindfoot Arthrodesis Intramedullary Nail - Foot & Ankle

WebApr 14, 2024 · The nail is designed for two 6.5 mm titanium recon screws in 130° CCD recon locking holes in the reconstruction locking mode at an anatomic anteversion of 14°. All … WebThumb Screw for the Synthes Recon Locking Aiming Arm for Lateral Entry Femoral Nails-EX (part number 03.010.048) and the Thumb Screw for the Aiming Arm for Titanium … WebMar 4, 2013 · START NOW. Also Available. Instruments. 03.010.042 Cannulated Connecting Screw, for Percutaneous Insertion Handle. 03.010.046 Percutaneous Insertion Handle. … military university uk

Class 2 Device Recall Synthes Recon Locking Aiming Arm for …

Category:DePuy Synthes Launches Innovative Nailing System Aimed At …

Tags:Synthes recon nail

Synthes recon nail

Gamma3 Hip Fracture Nailing System Stryker

Webdepuy synthes trauma solutions : dhs system: distal radius sterile kit: dynacord : ... femoral recon nail system (frn) fms vue : g.s.s : gii quick anchor plus system : global advantage: … WebSE_793147 AC page 2 / 6 Instructions for Use Femoral Recon Nail, Greater Trochanter B 9 mm Right Left Length 04.033.958S 04.033.959S 280 04.033.960S 04.033.961S 300

Synthes recon nail

Did you know?

WebThis nail bend is the same as for the TFN-Advanced Proximal Femoral Nail and the FRN-Advanced Femoral Recon Nail. The RFN-A is made of the same material as the TN-A (Ti … WebThe Synthes Titanium Trochanteric Fixation Nail (TFN) System permits an intramedullary approach for the fixation of frac- tures of the femur. The TFN System consists of a series …

WebJan 16, 2012 · The purpose of our study was to compare the proximal femoral nail antirotation (PFNA; Synthes, Paoli, Pennsylvania) with a reconstruction nail (Recon; … WebThe T2 Femoral Nailing System offers a universal left and right nail in addition to an antegrade or retrograde approach that may reduce inventory. The T2 IM Nailing Platform offers a combination of innovation, simplicity and versatility that is designed to suit your various needs. Retrograde vs. antegrade target device. 10mm of active compression.

WebMay 7, 2012 · Length in mm. 66 DePuy Synthes Femoral Recon Nail System (FRN) Surgical Technique 6.5 mm Titanium Recon Screws*, with T25 STARDRIVE Recess, for IM Nails. … Websynthes.hs.llnwd.net

WebEquipment. hindfoot arthrodesis intramedullary nailing system (Stryker T2 Hindfoot Nail System) 4.0mm cancellous screws, 2.5mm drill (Synthes Small Fragment Set) 1.6mm …

WebThe T2 Alpha Tibia Nailing System is intended for temporary stabilization of bone segments or fragments until bone consolidation has been achieved for tibial fractures. Indications … new york times the ethicist columnWebFeb 17, 2015 · Thumb Screw for the Synthes Recon Locking Aiming Arm for Lateral Entry Femoral Nails-EX (part number 03.010.048) and the Thumb Screw for the Aiming Arm for … new york times the lottery by shirley jacksonWebMay 1, 2024 · The antegrade femoral nailing was modeled on a Synthes Recon Nail (DePuy Synthes, West Chester, Philadelphia), with specific techniques such as guidewire entry … new york times the morningWebSynthes has not tested compatibility with devices provided by other manufacturers and assumes no liability in such instances. page 3 / 10 ... – The Antegrade Femoral Nail with … military unturned idWebDepuy Synthes, www.depuysynthes.com. 1.5: Unsafe 1 More... External Fixation Devices More... Adjustable External Fixation Device external fixation device carbon composite, SS … new york times the trouble with empathyWebJan 31, 2024 · DePuy Synthes** is launching the Femoral Neck System, a new implant solution for the repair of femoral neck fractures. Approximately 1.6 million hip fractures, … new york times the morning newsletterWebsynthes.vo.llnwd.net new york times the run up